We use our own and third-party cookies for analytics purposes and to display ads related to your preferences based on your browsing habits and your profile. You can configure or reject cookies by clicking on „Cookies Settings”. You can also accept all cookies by clicking „Accept Cookies” button. Please visit our website for more information. Privacy notice.

FAKRO official store

FXR G31 Fixed Curb-Mounted Skylight with Laminated Low-E Glass

from$432.00

Select variant to see more information

Size

Select
Unit of measurement:Inch

Product information available after selecting variant
Availability
Available
Lead time
8 working days
Item number
80FB19

A flashing is required to complete installation
You can purchase it here

Delivery
Check free delivery

The FXR is a curb-mounted fixed skylight designed to bring natural daylight into interior spaces in new construction and retrofit projects. Its simple, versatile design combines moisture-resistant construction with heat-reflecting laminated glazing, offering a practical solution for flat and sloped roofs.

 

Key features of the FXR fixed skylight include:

  • Laminated Glazing: Equipped with the G31 double-pane, Low-E glazing unit featuring a tempered exterior pane, laminated interior pane, warm spacer, and argon gas fill.
  • Thermal Performance: Whole-unit U-factor: 0.49, SHGC: 0.26, and visible transmittance (VT): 0.51.
  • Moisture-Resistant Construction: Non-absorbent materials resist moisture and corrosion, making the skylight suitable for rooms such as kitchens and bathrooms.
  • Versatile Curb Fit: Designed for site-built wooden curbs made from standard 2x4, 2x6, or 2x8 lumber.
  • Available Sizes: Offered in three nominal sizes: 22x22, 22x34, and 22x46.
  • Standard glazing units are suitable for installation up to 3,000 ft above sea level.

 

What's in the Box:

  • FXR G31 fixed skylight
  • Mounting screws

 

A properly flashed curb is required. For roof pitches between 15° and 60°, select the appropriate curb-mounted flashing kit based on the roof covering:

  • EH-C flashing – for tile, standing seam, and corrugated metal roofs
  • EL-C flashing – for shingles and other flat roofing materials

For roof pitches between 0° and 14°, the curb must be flashed with the appropriate roofing membrane in accordance with the FXR installation instructions. The curb and flashing are not included.

 

The skylight is backed by a 10-year limited warranty on the skylight and insulating glass seal, plus a 20-year warranty against hail breakage of laminated glass (subject to the limitations and exclusions specified in the product warranty terms).

 

All dimensions below are in inches. The nominal size is a model designation; use the inside and outside curb dimensions when selecting a skylight.

SKU#   80FB05 80FB19 80FB20
Size   22x22 22x34 22x46
Outside Curb (WxR) in. 25½x25½ 25½x37½ 25½x49½
Inside Curb (BxK) in. 22½x22½ 22½x34½ 22½x46½
Frame External Size (SxL) in. 27¼x27¼ 27¼x39⅛ 27¼x51¼